During its self-test, the Sunny Boy Control automatically detects the installed interfaces
(RS232, RS485, Powerline). Data transmission is always 8 data bits, no parity, and
one stop bit. The Baud rate can be changed only for the RS232 interface.
Menu “Setup…Modem/Fax…Modem”:
Interface deactivated
Device model
Hayes
Init-String AT&FE0V1X0Q0L2M1
ATS0=1
AT&D0&W
Dialmode
tone (MFW)
Table 10.6: Default modem settings
Menu “Setup…Interfaces…Ext. Display”:
Interface deactivated
Type EnergieCom
Configuration
Display 01: SC:Pac 4.0
Display 02: SC:E-total 4.0
Display 03: SC:E-today 4.0
Display 04: SC:Pac 6.2
Display 05: SC:E-total 6.2
Display 06: SC:E-today 6.2
Table 10.7: Default external display settings
Menu “Setup…System”:
Parameter Setting
Measuring interval
15.00 min
Table 10.8: Default settings in the “DAS Config” menu