50

LINCS Central Control

707024-002

L denotes a Local Sequence, and G denotes a Global Sequence. If both local and global
sequences are defined for a PF key, the local sequence takes precedence. You can only modify
the local sequences for the port that the device is attached to.

Local Playback Sequences Commands

On this panel, you can:

• Delete the Local PF key sequences - Enter D in the command column of the PF keys to

delete. Press PF10 to save the changes.

• Modify the Playback Name for PF key sequences - Type the new name in the playback

name field for the desired PF keys. Press PF10 to save the changes.

• Copy local sequences to global sequences - If you specified the update parameter to

enter this panel, then you can copy the local sequences to global sequences. Enter C in
the command column of the local PF key sequence(s) to copy, then press PF10 to process
and save the global sequence modifications to disk.

Restore Local Playback Sequences

PF9-Restore is only displayed for the current port. It restores the Local playback sequences
for the current port from the system disk. The device must be configured to record in order for
this key to operate.

Save Local Playback Sequences

PF10-Save processes the panel and saves all the currently defined local playback sequences
to the system disk. It is only displayed if the device profile used is configured to record (the
RPB Record Function has been enabled on the Device Profile/Display panel available from
the Configuration Main menu), and only for the current port.

Global Sequences Example

Global Playback Sequences

LINCS C8.2 Central Control

CMD

Playback Name

length

CMD

Playback Name length

G

PF1

.

LOGOFF.........

44

PF13

.

..............

0

PF2

.

...............

64

PF14

.

..............

0

PF3

.

................

0

PF15

.

..............

0

G

PF4

.

MY.CONNECT......

32

PF16

.

..............

0

. . . . . . . .

PF12

.

...............

0

PF24

.

..............

0

Commands

D = Delete Global SequenceRPB Sequences ID: _________

PF1-Menu3-Return 9-Restore 10-Save

If you press PF3-Disp_Globals from the local Playback Sequences panel, you will see this
panel with all global sequences. Access to the global sequences is configured by enabling the
Global Sequence Access field on the Device Profile/Display panel (available from the
Configuration Main menu).