Chapter 14. Online Testing

707024-002

ESCON Traffic Monitor: ESC1 LINCS C8.2 Central Control

Status: ENABLED

CU Index: ALL

Address: ** (enter Hex Value or “**” for ALL Addresses)

PF: 1-Menu 4-Stop

Since the ESCON Traffic Monitor runs by default, you must first stop the monitor, before
you can make changes to what it is to capture. When the monitor is running you should see
a status of ‘ENABLED’ displayed and a PF4-Stop key defined. Stop the monitor by pressing
the key. When the monitor stops, you will see the status change to ‘DISABLED’, and
the ‘PF4-Stop’ key will go away. You will also notice three new PF keys defined:

• PF3 – Start
• PF5 – Clear
• PF10 – Save

Pressing the key will restart the monitor, leaving the existing trace intact. Pressing the
key will clear the monitor. Pressing the key will save the current contents of
the trace into a binary file with the name of ‘ESC_DEV.BIN’. This file can be found in the
System directory. Note that if you want to save more than one trace, you will need to copy
the trace file off after each save, since the new save will overwrite the previous file.

An example of a captured ESCON trace is shown below.

Display Monitor for Line: ESC1 LINCS C8.2 Central Control

EVENT MESSAGE DESCRIPTION EXTENDED DATA

0000 T C7000606 Outbound Protocol Msg Addr = 00 Msg = COMM REM

0001 < 8D000400 Go Offline

0002 T C7000606 Outbound Protocol Msg Addr = 00 Msg = COMM REM

0003 T C7100606 Outbound Protocol Msg Addr = 10 Msg = COMM REM

0004 < 8B000606 Go Online

0005 > 0E000406 ESCON Link Error Addr = 00 Flags = 04 Seq # = 06

0006 > 0E010406 ESCON Link Error Addr = 01 Flags = 04 Seq # = 06

0007 < 8C100406 Logical Path Est. LPAR = 01 Addr = C0 CUI = 01

0008 > 0E030406 ESCON Link Error Addr = 03 Flags = 04 Seq # = 06

0009 > 0E040406 ESCON Link Error Addr = 04 Flags = 04 Seq # = 06

0010 > 0E050406 ESCON Link Error Addr = 05 Flags = 04 Seq # = 06

0011 T C7100606 Outbound Protocol Msg Addr = 10 Msg = COMM REM

0012 T C7100606 Outbound Protocol Msg Addr = 10 Msg = COMM REM

0013 > 0E080406 ESCON Link Error Addr = 08 Flags = 04 Seq # = 06

0014 > 0E080406 ESCON Link Error Addr = 08 Flags = 04 Seq # = 06

0015 < 8C000406 Logical Path Est. LPAR = 03 Addr = C0 CUI = 00

0016 T C7000606 Outbound Protocol Msg Addr = 00 Msg = COMM REM

PF: 1-Menu 8-Forw

Events are numbered in the trace sequentially. A greater than symbol (>) is used to indicate
outbound traffic (from the host) and the less than symbol indicates inbound traffic (to the
host). The letter ‘T’ is used to denote Inbound and Outbound Protocol Messages exchanged