beautypg.com

Appn audits, Summary counters – Visara LINCS Central Control User Manual

Page 105

background image

99

Chapter 12. Event Logs Menu

707024-002

APPN Audits

This log displays the Audits recorded by the APPN feature when configured. Audits are logged
in chronological order, but upon entering the APPN Audits utility, the last Audit is displayed.
You can page forwards and backwards through the Audits log to display each Audit, one per
page. An example of what one of these Audits looks like is shown below.

APPN Audits LINCS C8.2 Central Control

Event Data

Beginning of Trace Buffer>

0000 APPN_Audit 05/24/05, 12:10.04, 4380432

Message 252:0 (from C:\DIAB\WORK\DCL$NOFINIT.C)

Node started

CP name (Alias) = VISARA.VIS1 (VIS1)

Node type = 02

Node info = LINCS Network Node, MTX, Inc.

PF: 1-Menu 8-Forw

Summary Counters

This log displays summary counters for 200 and 500 series errors for the host circuit that the
display viewing the panels is connected to. This is a good log to start with to get an idea of the
type of event codes being logged. For a more complete definition of the error codes listed,
refer to the LINCS Problem Determination Manual.

Summary Counters

LINCS C8.2 Central Control

200 Summary Counters

500 Summary Counters

201_03 31

505_01 01

211_01 01

505_10 03

531_60 01

532_02 01

532_03 02

PF: 1-Menu

Clear All Summary Counters

Password protected. Selection 7 erases the summary counters. A 100-21 will be displayed in
the event log to indicate that the summary counters were cleared.

Clear All Event Logs

Password protected. Selection 8 erases the event logs. When the logs are cleared, Code 174-20
will be logged in the Event Log.