Visara SCON-20L Configuration Manual User Manual
Page 82

9-10
707044-006
SCON-20L/22L/25L/28L Configuration Manual
Device Type
This field indicates whether devices that use the profile will be displays or printers.
Storagetek LMUs are defined as displays. The value chosen here determines the
parameters that will be displayed on subsequent panels in the profile.
Power Off Action
This is a toggle field that defines what will happen to sessions connected to a host when
the device powers off. The following are the options.
• None - The session state will remain intact when the device powers off.
• Unbind SNA Sessions - This option does not apply to SCON-2XL sessions since
they are Non-SNA.
• Disconnect all Sessions - All sessions connected to a host will be disconnected when
the device powers off. This frees up the host resources for connection by other devices.
Session
This is a protected field which identifies the 10 sessions which are available on
each device. It is used in conjunction with the Default Host Assignments field to
uniquely identify each session.
Default Host Assignments
These fields are used to assign hosts to device sessions. The host assignments defined
in the Device Profile serve as the default host assignments for all devices which are
assigned that profile.
Each session (A-J) has a field which defines a host assignment. This field toggles to all
available hosts, all classes, the connect menu, or disable.
These default host assignments may be overridden on the Device Profile Assignments
panel.
Below is a description of the types of Host Assignments that may appear.
3270 Host Class
If 3270 Host Classes (pools) were defined previously, each class defined would appear
as possible options.