beautypg.com

Abort output, Are you there, Binary – Visara SCON-20L Configuration Manual User Manual

Page 50: Break character, Echo, Erase character, Erase line, Interrupt process

background image

5-8

707044-006

SCON-20L/22L/25L/28L Configuration Manual

Interrupt Process

This field lets you define the ASCII character that will generate the Interrupt Process
character for TELNET.

The valid range is 00 to 31 decimal. 00 is the default and disables the option.

Abort Output

Defines the ASCII character that will generate the Abort Output Character for TELNET.

The valid range is 00 to 31 decimal. 00 is the default and disables the option.

Break Character

Defines the ASCII character that generates the Break Character for TELNET.

The valid range is 00 to 31 decimal. 00 is the default, and disables the option.

Are You There

Defines the ASCII character that will generate the Are You There character for TELNET.

The valid range is 00 to 31 decimal. 00 is the default and disables the option.

Erase Character

Defines the ASCII character that will generate the Erase Character for TELNET.

The valid range is 00 to 31 decimal. 00 is the default and disables the option.

Erase Line

Defines the ASCII character that will generate the Erase Line Character for TELNET.

The valid range is 00 to 31. 00 is the default and disables the option.

Echo

Enabling this option will cause all characters sent to the host to be echoed to the screen.
See RFC 857 for more detail.

Binary

Enabling this option allows binary communication upon receipt of standard codes. See
RFC 856 for more detail. This is required for TN3270/TN3270E.