Parameter, J1587, J1939 – Gasboy Fuel Point PLUS Vehicle User Manual
Page 98: Default, Alternative, Odometer adr, Dp odo adr, E.h adr, Dp e.h adr, E.h pid

Fuel Point PLUS Vehicle Installation and Configuration Manual
98
4-5.1.
Setting DP-Heavy Vehicle Interface Communication Parameters
Table 4-12 shows default and alternative values for DP-vehicle interface communication parameters
described above.
Table 4-12. DP – Heavy Vehicle Interfaces Communication Parameters Values
Parameter
J1587
J1939
Default
Alternative
Default
Alternative
Odometer Adr
255
128
255
0
DP Odo Adr
141
171, 179, 180
24
-
E.H Adr
255
128
255
0
DP E.H Adr
141
171, 179, 180
24
-
E.H PID
247
246
229
In cases where Odometer and Engine Hour readings are not obtained using default values proceed
as follows:
Odometer reading:
If Odometer reading is 0/ fails: Change DP Odo Adr to one of the alternative values shown
above
Engine Hour reading:
If E.H. reading fails: Change DP E.H Adr to one of the alternative values shown above
If E.H. reading still fails – change E.H PID to 246