Fuel Point PLUS Vehicle Installation and Configuration Manual

98

4-5.1.

Setting DP-Heavy Vehicle Interface Communication Parameters

Table 4-12 shows default and alternative values for DP-vehicle interface communication parameters

described above.

Table 4-12. DP – Heavy Vehicle Interfaces Communication Parameters Values

Parameter

J1587

J1939

Default

Alternative

Default

Alternative

Odometer Adr

255

128

255

0

DP Odo Adr

141

171, 179, 180

24

-

E.H Adr

255

128

255

0

DP E.H Adr

141

171, 179, 180

24

-

E.H PID

247

246

229

In cases where Odometer and Engine Hour readings are not obtained using default values proceed

as follows:

Odometer reading:

If Odometer reading is 0/ fails: Change DP Odo Adr to one of the alternative values shown

above

Engine Hour reading:

If E.H. reading fails: Change DP E.H Adr to one of the alternative values shown above

If E.H. reading still fails – change E.H PID to 246