Fuel Point PLUS Vehicle Installation and Configuration Manual

130

Table A-2. DP Calibration Sequence

Step

Display

Description/Action

1

Enter User ID

Enter password.

2

The Main Menu is displayed.

3

Use the DOWN arrow key to move the pointer

(>) to the Calibrate DP option

4

Use the DOWN arrow key to move the pointer

(>) to the Read DP by Address option

6

DP MAC address (unique unit ID) insertion:

Enter 1 to automatically recognize DP MAC

address. Stay inside the vehicle close to DP,

or at a maximum range of ~0.5m to maintain

proper receiving signal and avoid the

possibility of finding by mistake another DP.

Wait up to seven seconds for result

Enter 2 for manual insertion of the MAC

address

7

Verify the automatically entered MAC/Type the

eight characters as shown on DP rear label and

save

8

Wait a few seconds until the WP recognizes the

DP

9

Enter the current odometer reading