beautypg.com

Step, Display, Description/action – Gasboy Fuel Point PLUS Vehicle User Manual

Page 108: If programming μdp (not μdp+), proceed to step 34, Error codes collection option. default: n, Press enter to leave the option disabled, Change default to y to enable the option, Idle time collection option. default: n, Over speed collection option. default: n, This parameter is available for μdp+ can

background image

Fuel Point PLUS Vehicle Installation and Configuration Manual

108

Step

Display

Description/Action

24

This screen is displayed only in cases where

Odometer reading was not disabled.

Edit the parameter, entering the value displayed

on the dashboard

25

This screen is displayed only in cases where

E.H. reading was not disabled.

Edit the parameter, entering the value displayed

on the dashboard (if available)

If programming μDP (not μDP+), proceed to

Step 34

26

Error codes collection option. Default: N

Press ENTER to leave the option disabled

Change default to Y to enable the option

27

Idle Time collection option. Default: N

Press ENTER to leave the option disabled.

In this case, proceed to step 29

Change default to Y to enable the option

28

Idle Time Threshold. Default: Five minutes. Save

or edit the parameter and save

29

Over Speed collection option. Default: N

Press ENTER to leave the option disabled.

In this case, proceed to step 31 for

μDP+ Can or to step 33 for μDP+ K-

Line

Change default to Y to enable the option

30

Over Speed Threshold. Default: 70 miles/113

Km. Save or edit the parameter and save

31

This parameter is available for μDP+ Can.

Over RPM collection option. Default: N

Press ENTER to leave the option disabled.