Step, Display, Description/action – Gasboy Fuel Point PLUS Vehicle User Manual
Page 108: If programming μdp (not μdp+), proceed to step 34, Error codes collection option. default: n, Press enter to leave the option disabled, Change default to y to enable the option, Idle time collection option. default: n, Over speed collection option. default: n, This parameter is available for μdp+ can

Fuel Point PLUS Vehicle Installation and Configuration Manual
108
Step
Display
Description/Action
24
This screen is displayed only in cases where
Odometer reading was not disabled.
Edit the parameter, entering the value displayed
on the dashboard
25
This screen is displayed only in cases where
E.H. reading was not disabled.
Edit the parameter, entering the value displayed
on the dashboard (if available)
If programming μDP (not μDP+), proceed to
Step 34
26
Error codes collection option. Default: N
Press ENTER to leave the option disabled
Change default to Y to enable the option
27
Idle Time collection option. Default: N
Press ENTER to leave the option disabled.
In this case, proceed to step 29
Change default to Y to enable the option
28
Idle Time Threshold. Default: Five minutes. Save
or edit the parameter and save
29
Over Speed collection option. Default: N
Press ENTER to leave the option disabled.
In this case, proceed to step 31 for
μDP+ Can or to step 33 for μDP+ K-
Line
Change default to Y to enable the option
30
Over Speed Threshold. Default: 70 miles/113
Km. Save or edit the parameter and save
31
This parameter is available for μDP+ Can.
Over RPM collection option. Default: N
Press ENTER to leave the option disabled.