Gasboy Fuel Point PLUS Vehicle User Manual
Page 85

Fuel Point PLUS Vehicle Installation and Configuration Manual
85
Parameter
Description
Odometer Threshold Oscillation amplitude to be identified as a pulse (1), as
provided by the vehicle manufacturer (in cases where
the value is unknown, set a threshold of 2000 mV)
Odometer Hysteresis Amplitude threshold to be identified as no pulse (0) for
noise elimination (in cases where the value is
unknown, set the hysteresis to 200 mV)
DP Factor
Odometer reading calibration factor for different OBD-
II interface vehicle models
DP Offset
Offset value for calibration of Odometer readings in
different OBD-II interface vehicle models
Aux EH Polarity
Auxiliary Engine Hour counter setup, according to the
available physical connection, as follows:
Select Plus if Aux Engine starts to operate
when the line go from zero to 12V (from 0 to 1
state)
Select Minus to start counting in power drop,
from 12V to zero (from 1 to 0 state)
In cases where the vehicle chassis is the positive output
line, please call Professional Services for support.
NOTE
For further information on DP- heavy vehicles
interface communication parameters settings, please
refer to para. 4-5.1.