beautypg.com

Gasboy Fuel Point PLUS Vehicle User Manual

Page 85

background image

Fuel Point PLUS Vehicle Installation and Configuration Manual

85

Parameter

Description

Odometer Threshold Oscillation amplitude to be identified as a pulse (1), as

provided by the vehicle manufacturer (in cases where

the value is unknown, set a threshold of 2000 mV)

Odometer Hysteresis Amplitude threshold to be identified as no pulse (0) for

noise elimination (in cases where the value is

unknown, set the hysteresis to 200 mV)

DP Factor

Odometer reading calibration factor for different OBD-

II interface vehicle models

DP Offset

Offset value for calibration of Odometer readings in

different OBD-II interface vehicle models

Aux EH Polarity

Auxiliary Engine Hour counter setup, according to the

available physical connection, as follows:

Select Plus if Aux Engine starts to operate

when the line go from zero to 12V (from 0 to 1

state)

Select Minus to start counting in power drop,

from 12V to zero (from 1 to 0 state)

In cases where the vehicle chassis is the positive output

line, please call Professional Services for support.

NOTE

For further information on DP- heavy vehicles

interface communication parameters settings, please

refer to para. 4-5.1.