SECTION 5
TROUBLESHOOTING
5-1.
GENERAL
Table 5-1 provides a list of common problems related to the vehicle units or to its communication
with the Fuel Point PLUS system, as well as corrective action instructions.
Table 5-1. Troubleshooting Guide
No.
Fault
Probable Cause
Corrective Action
Sending Data to Server
1.
During programming of Fuel
Ring and DataPass, No VIU
Detected. Retry?
message
appears on screen.
1. ID chip is cut-off
from coil
Verify that ID chip is
properly connected to coil
2. Distance between
WP and FR is too
far
Bring the WP closer to FR
3. ID chip is damaged
Replace ID chip
2.
During programming of Fuel
Ring and DP, DP Read Error.
Retry?
message appears on
screen.
1. DP is not powered
Check power connection to
DP
2. Wrong setting of
DP Address
Set DP address properly
3. Defective DataPass
Replace DataPass
4.
DP
–VIU Was In Use message
appears on screen.
1. DataPass previously
used in other
vehicle
Replace DataPass with a
new one
Erase previously used DP
5.
DP
–WP Write Error message
appears on the screen.
WP coil and coil are too
far from each other, or
bad wiring
1. Check DataPass wiring
2. Place Testing coil closer
to tested coil and try
again
6.
Programmer not functioning
(cannot read parameters from
vehicle)
Defective Programmer
Verify that the programmer
is operational on another
vehicle