beautypg.com

Gasboy Fuel Point PLUS Vehicle User Manual

Page 122

background image

Fuel Point PLUS Vehicle Installation and Configuration Manual

122

SECTION 5

TROUBLESHOOTING


5-1.

GENERAL

Table 5-1 provides a list of common problems related to the vehicle units or to its communication

with the Fuel Point PLUS system, as well as corrective action instructions.

Table 5-1. Troubleshooting Guide

No.

Fault

Probable Cause

Corrective Action

Sending Data to Server

1.

During programming of Fuel

Ring and DataPass, No VIU
Detected. Retry?

message

appears on screen.

1. ID chip is cut-off

from coil

Verify that ID chip is

properly connected to coil

2. Distance between

WP and FR is too

far

Bring the WP closer to FR

3. ID chip is damaged

Replace ID chip

2.

During programming of Fuel

Ring and DP, DP Read Error.
Retry?

message appears on

screen.

1. DP is not powered

Check power connection to

DP

2. Wrong setting of

DP Address

Set DP address properly

3. Defective DataPass

Replace DataPass

4.

DP

VIU Was In Use message

appears on screen.

1. DataPass previously

used in other

vehicle

Replace DataPass with a

new one

Erase previously used DP

5.

DP

WP Write Error message

appears on the screen.

WP coil and coil are too

far from each other, or

bad wiring

1. Check DataPass wiring

2. Place Testing coil closer

to tested coil and try

again

6.

Programmer not functioning

(cannot read parameters from

vehicle)

Defective Programmer

Verify that the programmer

is operational on another

vehicle