G (table b-8), G (table b-9) – Basler Electric BE1-851 User Manual
Page 355
![background image](https://www.manualsdir.com/files/773789/content/doc355.png)
ASCII Command
Function
HMI Screen
SG-CT[t][={CT_ratio}]
Read/Set Phase/Neutral CT ratio.
6.3.1
SG-DI[p][={interval}]
Read/Set P(IA/IB/IC/var/watt), N and Q
demand interval.
N/A
SG-DSP[P/N][=A/F/R]
Read analog signal dsp filter type.
N/A
SG-DST[=1/2]
Read/Set Daylight Saving Time type.
N/A
SG-DSTSTART[={Mo,D,H,M,O}]
Read/Set settings for start of Daylight
Saving Time.
N/A
SG-DSTSTOP[={Mo,D,H,M,O}]
Read/Set settings for end of Daylight
Saving Time.
N/A
SG-FREQ[={freq(HZ)}]
Read/Enter power system frequency.
6.3.2
SG-HOLD[n][={1/0 hold ena}]
Read/Program output hold operation.
N/A
SG-ID[={relayID(up to 30 char)},{StationID(up to 30
char)}]
Read/Set relay ID and station ID used in
reports.
N/A
SG-IN[#[={r(ms)},{db(ms)}]]
Read/Set input recognition/debounce.
N/A
SG-SCREEN[n][={default screen number}]
Read/Set default screen(s).
N/A
SG-SGCON[={time}]
Read/Set SGC output time.
N/A
SG-TARG[={x/x/..x},{rst TARG logic}]
Report/Enable Target list and Reset
Target logic.
N/A
SG-TRIGGER[={TRIP trigger},{PU trigger},
{LOGIC trigger}]
Read/Set trigger logic.
N/A
SG-UTC[=M,R,B]
Read/Set UTC information for Daylight
Saving Time.
N/A
Table B-8. Breaker Monitoring and Setting Commands
ASCII Command
Function
HMI Screen
SB
Read all breaker settings.
N/A
SB-DUTY[={mode},{dmax},{BLKBKR logic}]
Read/Set breaker contact duty.
N/A
SB-LOGIC[={breaker close logic}]
Read/Set breaker contact logic.
N/A
Table B-9. Programmable Logic Setting Commands
ASCII Command
Function
HMI Screen
SL:[{name}]
Obtain setting logic information.
N/A
SL-x50T[{p}[={mode},{BLK logic}]]
Read/Set logic for 50 function modules.
N/A
SL-x51[{p}[={mode},{BLK logic}]]
Read/Set logic for 51 function modules.
N/A
SL-{f}62[={mode},{INI logic},{BLK logic}]
Read/Set logic for 62 function modules.
N/A
SL-79[={mode},{RI logic},{STATUS logic},
{WAIT logic},{LOCKOUT logic}]
Read/Set for 79 function.
N/A
SL-BF[{p}[={mode},{INI logic},{BLK logic}]]
Read/Set logic for breaker failure function
modules.
N/A
SL-GROUP[={mode},{D0logic},{D1logic},{D2logic},
{D3logic},{AUTOlogic}]
Read/Set logic for setting group module.
N/A
SL-N[={name}]
Read, set, or copy the name of the
custom logic.
N/A
SL-VO[x[={Boolean equation}]]
Read/Set output logic.
N/A
SL-{x}43[=mode]
Read/Set logic for Virtual Switches.
N/A
SL-101[=mode]
Read/Set logic for Virtual Breaker Control
Switch.
N/A
9289900990 Rev R
BE1-851 Command Cross-Reference
B-3