Recloser (79), Active group, Breaker (52) – Basler Electric BE1-851 User Manual
Page 108: Diag/alarm, Other rg commands, Other rg commands -6

Table 6-4. Logic Variable Status Report Format for Sensing Input Type G Relays
5
0
T
P
T
1
5
0
T
P
T
5
0
T
N
T
1
5
0
T
N
T
2
5
0
T
N
T
3
5
0
T
N
T
B
F
T
5
1
P
T
5
1
N
T
5
1
Q
T
5
0
T
P
P
U
1
5
0
T
P
P
U
5
0
T
N
P
U
1
5
0
T
N
P
U
2
5
0
T
N
P
U
3
5
0
T
N
P
U
B
F
P
U
5
1
P
P
U
5
1
N
P
U
5
1
Q
P
U
6
2
1
6
2
4
3
∗
1
4
3
∗
2
4
3
∗
3
4
3
∗
7
9
C
7
9
R
N
G
7
9
L
O
7
9
F
7
9
S
C
B
S
P
A
R
E
0
0
0
1
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
9
1
0
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
8
2
9
3
0
3
1
V
O
A
V
O
1
V
O
2
V
O
3
V
O
4
V
O
5
V
O
6
V
O
7
V
O
8
V
O
9
V
O
1
0
V
O
1
1
V
O
1
2
V
O
1
3
V
O
1
4
V
O
1
5
I
N
1
I
N
2
I
N
3
I
N
4
1
0
1
T
1
0
1
C
1
0
1
S
C
R
S
T
K
E
Y
A
L
M
L
G
C
A
L
M
M
A
J
A
L
M
M
I
N
O
U
T
1
M
O
N
S
G
0
S
G
1
S
G
2
S
G
3
3
2
3
3
3
4
3
5
3
6
3
7
3
8
3
9
4
0
4
1
4
2
4
3
4
4
4
5
4
6
4
7
4
8
4
9
5
0
5
1
5
2
5
3
5
4
5
5
5
6
5
7
5
8
5
9
6
0
6
1
6
2
6
3
∗
The following applies when style option 1 is V or W.
Logic Bit Function
22
262
23
362
24
43
25
143
See Tables 7-1 and 7-2, Logic Variable Names and Descriptions, for a cross-reference of each BESTlogic
bit.
Recloser (79)
The status of the recloser is reported on this line. HMI Screen 1.1 also reports this information. More
information about the recloser function is available in Section 4, Protection and Control Functions.
Active Group
The active group is indicated on this line. HMI Screen 1.5.5 also provides this information. See Section 4,
Protection and Control, for more information about setting groups.
Breaker (52)
This line reports the state of the breaker. This information is also available at HMI Screen 1.5.6. More
information about breaker status is provided in the Breaker Monitoring subsection.
Diag/Alarm
This line reports the status of the Relay Trouble Alarm, Major Alarm, Minor Alarm, and Logic Alarm. The
status of these alarms can be viewed at HMI Screen 1.3. Front panel LEDs also indicate the status of the
Relay Trouble Alarm, Minor Alarm, and Major Alarm. Alarm status is also available through the
communication ports. The SA-MIN command reports the Minor Alarm status, the SA-MAJ command
reports the Major Alarm status, and the SA-LGC command reports the Logic Alarm status.
Other RG Commands
There are several other RG commands in addition to the RG-STAT command. These include RG-TIME,
RG-DATE, RG-TARG, and RG-VER. These commands are covered in detail in respective paragraphs in
6-6
BE1-851 Reporting and Alarms
9289900990 Rev R