Feed input, Pause input, Start error stop – Avery Dennison Monarch 9864 Info Printouts and Parameters User Manual
Page 92: Internal inputs

06/08 Rev. AB
USER MANUAL
Info-Printouts & Parameters
9844 - 9854 - 9864
92
Feed input
9864
¯
Only with USI board.
Sets how the output signal FEED at the USI is handled.
Standard
(Default setting) Feeds blank labels when the signal is low.
Precondition: Offline mode or printing stopped in online mode.
Pause input
9864
¯
Only with USI board.
Sets how the output signal PAUSE of the USI is handled.
Standard
(Default setting) A low signal for 20 ms pauses the DPM / PEM. The pause
status is the same as the on-line stopped status and can be exited by
pressing Feed.
Start error stop
9864
¯
Only with USI board.
Sets how the printer reacts to a product start error. A product start error
occurs when
•
another start signal arrives before the current label is finished printing.
•
a reprint is requested before the first label is printed.
•
a start signal arrives and no print job is loaded.
The printer stops for a start error and displays an error message. At the same
time, the following output signals are on (set low):
•
ERROR
•
MACHINE STATUS
On
The printer stops for a start error (default setting).
Off
Start errors are ignored.
Internal inputs
9864
¯
Only with USI board.
Sets if the internal inputs (CN300) on the USI board are used.
Enabled
The internal inputs are on.
Disabled
The internal inputs off.