Feed input

9864

¯

Only with USI board.

Sets how the output signal FEED at the USI is handled.

Standard

(Default setting) Feeds blank labels when the signal is low.
Precondition: Offline mode or printing stopped in online mode.

Pause input

9864

¯

Only with USI board.

Sets how the output signal PAUSE of the USI is handled.

Standard

(Default setting) A low signal for 20 ms pauses the DPM / PEM. The pause
status is the same as the on-line stopped status and can be exited by
pressing Feed.

Start error stop

9864

¯

Only with USI board.

Sets how the printer reacts to a product start error. A product start error
occurs when

another start signal arrives before the current label is finished printing.

a reprint is requested before the first label is printed.

a start signal arrives and no print job is loaded.

The printer stops for a start error and displays an error message. At the same
time, the following output signals are on (set low):

ERROR

MACHINE STATUS

On

The printer stops for a start error (default setting).

Off

Start errors are ignored.

Internal inputs

9864

¯

Only with USI board.

Sets if the internal inputs (CN300) on the USI board are used.

Enabled

The internal inputs are on.

Disabled

The internal inputs off.