Singlestartquant
9864
9844
9854
Single start quantity
xx
Setting range: 1 to 10; Unit interval: 1
External signal
9864
9844
9854
Sets how an incoming signal is interpreted.
Disabled
Signal interpretation disabled.
Singlestart
The signal triggers the printing of a single label. This setting may be used to
print single labels using a foot switch.
Stacker full
The signal triggers the display of a status report and stops the printer when
using a stacker (stacker full signal).
Dispensing mode
9864
¯
Only if
SYSTEM PARAMETER > Periph. device
= Dispenser.
¯
Only effective in Real 1:1 Mode!
Real 1:1 Mode may cause slippage at the rollers while feeding backwards.
The Dispensing mode parameter enables optimal positioned printouts even
in Real 1:1 Mode. This accuracy is reached by backing up the next label to
be printed behind the gap sensor instead under the printhead. The additional
distance of backwards feeding reduces the output rate slightly.
exact
Printout with a maximum impression accuracy
fast
Printout with a lower impression accuracy but higher output rate.
Application mode
9864
¯
Only if
SYSTEM PARAMETER > Periph. device
= Dispenser.
Save Mode
A start signal is required to back up the next label under the printhead.
Use for label material with a strong adhesive that would not stay attached to
the applicator when the backing paper is fed backwards.
Immediate Mode
After the printed label reaches the dispense position, the next label is backed
up under the printhead. The dispensed label stays attached to the applicator