beautypg.com

Dp interface, Interface type, Start delay – Avery Dennison Monarch 9864 Info Printouts and Parameters User Manual

Page 89

background image

06/08 Rev. AB

USER MANUAL

Info-Printouts & Parameters

9844 - 9854 - 9864

89

DP INTERFACE

¯

These parameters only appear in the parameter menu when a USI board

is installed.

Interface type

9864

¯

Only with USI board.

Sets the machine to use applicator.

USI interface

Setting for direct dispensing.

USI applicator

Setting for operation of an applicator with additional PLC.

Start delay

9864

¯

Only with USI board.

This parameter sets the distance between the product sensor (photoelectric
switch) and the dispensing edge. The delay time is calculated from the Start
delay distance and the conveyor speed (or print speed if using direct
application).

xxx.x mm

Setting range: 0.0 to 999.9 mm; Unit interval: 0.1 mm;
Default setting: 0 mm

¯

The start delay setting works with one of the following parameter Start

Print Mode settings:

Parameter

Setting

Start print mode

Pulse falling

Pulse rising

Pulse fall/ris

[15] To use Start delay, set one of the Start Print Mode settings.