Serial port mode, Frame error, Com4 port – Avery Dennison Monarch 9864 Info Printouts and Parameters User Manual
Page 42: Baud rate, Parity

06/08 Rev. AB
USER MANUAL
Info-Printouts & Parameters
9844 - 9854 - 9864
42
Serial Port Mode
9864
9844
9854
¯
With installed I/O board only.
Setting the serial interface.
RS232
Sets Com2 to RS 232.
Data synchronization may be done by hardware (RTS/CTS) or by software
(XON/XOFF). Maximum cable length is 15 m.
RS422
Sets Com2 to RS 422.
RS 422 is a 4-wire point-to-point connection, suitable for only one device.
Receiver and driver of the printer are always enabled. Data synchronization
is only possible by software (XON/XOFF). Maximum cable length is 1 km with
twisted telecommunication cable.
RS485
Sets Com2 to RS 485.
RS 485 is a 2 or 4-wire bus system for up to 30 devices. The printer´s receiver
is always enabled. The printer´s driver is only enabled if the printer sends
data to the host. Data synchronization is only possible by software (XON/
XOFF). Maximum cable length is 1 km with twisted telecommunication cable.
Frame error
9864
9844
9854
¯
With installed I/O board only.
P
> COM4 PORT
Internal interface for the optional RFID read/write unit connection.
Baud rate
9864
9854
¯
With installed I/O board only.
P
Parity
9864
9854
¯
With installed I/O board only.
P