Punch offset, Bar code multip – Avery Dennison Monarch 9864 Info Printouts and Parameters User Manual
Page 27
![background image](https://www.manualsdir.com/files/772971/content/doc027.png)
06/08 Rev. AB
USER MANUAL
Info-Printouts & Parameters
9844 - 9854 - 9864
27
Punch offset
9864
9844
9854
The zero position can be determined offset in millimeter units from the
detected gap position.
¯
The value is overwritten by the appropriate Easy Plug command when
sending label formats.
xxx mm
Setting range: -5 to +max. label length; Unit interval: 0.1mm
Default setting: 0 mm
Maximum offset in feed direction: -5 mm
Minimum offset against feed direction: +max. label length
[10] Positive and negative offset in relation to the feed direction (arrow).
Bar code multip.
9864
9844
9854
Bar code multiplication factor
Adjusts the bar code height by multiplying by a factor of 1 to 10 (BCHI
factor).
xxx mm
Setting range: 1 to 10; Unit interval: 1; Default setting: 1
The actual bar code height is calculated by multiplying the value defined in
the label layout (mask) by the bar code height enlargement factor.
Actual bar code height = (layout value + 1) * bar code height
Example:
The bar code height value is set = 3. With the Easy Plug command in the
label layout, the value /4/ is given as the bar code height (1 is standard).
Result: (4 + 1) * 3 = 15 mm.
The bar code is printed with a height of 15 mm.