Punch offset

9864

9844

9854

The zero position can be determined offset in millimeter units from the
detected gap position.

¯

The value is overwritten by the appropriate Easy Plug command when

sending label formats.

xxx mm

Setting range: -5 to +max. label length; Unit interval: 0.1mm
Default setting: 0 mm

Maximum offset in feed direction: -5 mm

Minimum offset against feed direction: +max. label length

[10] Positive and negative offset in relation to the feed direction (arrow).

Bar code multip.

9864

9844

9854

Bar code multiplication factor

Adjusts the bar code height by multiplying by a factor of 1 to 10 (BCHI
factor).

xxx mm

Setting range: 1 to 10; Unit interval: 1; Default setting: 1

The actual bar code height is calculated by multiplying the value defined in
the label layout (mask) by the bar code height enlargement factor.

Actual bar code height = (layout value + 1) * bar code height

Example:
The bar code height value is set = 3. With the Easy Plug command in the
label layout, the value /4/ is given as the bar code height (1 is standard).
Result: (4 + 1) * 3 = 15 mm.