Error output, Error polarity – Avery Dennison Monarch 9864 Info Printouts and Parameters User Manual
Page 77

06/08 Rev. AB
USER MANUAL
Info-Printouts & Parameters
9844 - 9854 - 9864
77
A low signal for 20 ms switches the printer into pause mode. Pause mode is
the same as Online stopped mode and can be switched to the Online mode
by pressing Feed.
Error output
9864
9844
9854
¯
Only with an I/O board installed.
This parameter defines what events generate an ERROR.
Printer error
ERROR appears in the following cases:
•
Material end
•
Ribbon end (only if
SYSTEM PARAMETER > Foil mode
= Thermo transfer)
•
No punch recognized (only if
PRINT PARAMETERS > Material type
= punched)
•
Printhead pressure lever was opened while printing.
•
Start print error
•
Other errors that prevent the printer from printing
¯
During the printer initialization, the ERROR signal is not available.
Printererr + Offl
ERROR also appears when
•
the printer is offline
•
the printhead pressure lever is open
•
I/O board pause mode
•
printing was stopped (stopped mode)
Error Polarity
9864
9844
9854
¯
Only with an I/O board installed.
Changes the polarity of the ERROR signal.
Level high active
The output is high when it is on, otherwise low.
Level low active
The output is low when it is on, otherwise high. (Default)