A low signal for 20 ms switches the printer into pause mode. Pause mode is
the same as Online stopped mode and can be switched to the Online mode
by pressing Feed.

Error output

9864

9844

9854

¯

Only with an I/O board installed.

This parameter defines what events generate an ERROR.

Printer error

ERROR appears in the following cases:

Material end

Ribbon end (only if

SYSTEM PARAMETER > Foil mode

= Thermo transfer)

No punch recognized (only if

PRINT PARAMETERS > Material type

= punched)

Printhead pressure lever was opened while printing.

Start print error

Other errors that prevent the printer from printing

¯

During the printer initialization, the ERROR signal is not available.

Printererr + Offl

ERROR also appears when

the printer is offline

the printhead pressure lever is open

I/O board pause mode

printing was stopped (stopped mode)

Error Polarity

9864

9844

9854

¯

Only with an I/O board installed.

Changes the polarity of the ERROR signal.

Level high active

The output is high when it is on, otherwise low.

Level low active