background image

06/08 Rev. AB

USER MANUAL

Info-Printouts & Parameters

9844 - 9854 - 9864

70

Key codes

Regardless when the code is prompted, three different key codes can be
entered [tab. 10].

Entering a key code: Press the control panel buttons in the sequence listed.
A valid key code switches the printer into the appropriate mode.

Possible Settings

Disabled

Password prompt turned off (default)

Power-up code

Displays the password prompt when the printer is turned on.

After the key code is entered, the printer starts in user or supervisor mode.

User

Displays the password prompt when accessing the parameter menu.

The printer starts in offline mode.

Changes to online mode are allowed.

To see the parameters-menu, enter a valid key code

Valid key codes: all

Supervisor

As setting User, with different valid key codes:

Valid key codes: Supervisor

User auto start

(Not with 9844) Printer starts without the password prompt. Only the menus

PRINT INFO

and

SERVICE DATA

are available.

Realtime clock

9864

9854

The realtime clock provides the actual date and time. Set the date and time
with the Easy Plug #YC, #YS or #DM commands.

Setting date / time:

1. Press Cut until the digit you need to change blinks.

2. Press Feed until you see the digit you need.

3. Repeat steps 1 and 2 until the date and time are set correctly.

4. Press Online.

¯

Press Esc to exit the parameter without changing the setting.

Enter code

Mode

Key code

Impact

User

2x Cut Feed, Online

Access only to the submenus

PRINT INFO

and

SERVICE DATA

Supervisor

2x Online, Feed, Cut, 2x Online

Access to all parameters
except production parameters

[10] Valid key codes.

Realtime Clock
dd.mm.yyyy hh:mm

dd=Day, mm=Month, yyyy=Year, hh=Hour,
mm=Minute (Example: 19.02.2001 14:41)