SYSTEM PARAMETERS
Foil end warning
9864
9844
9854
Sets the minimum ribbon roll to indicate “out of ribbon” when the value is
reached.
9864:
This message displays and a signal is set at the (optional) USI.
P
See parameters
DP INTERFACE > Ribbon signal
and
SERVICE DATA > OPERATION DATA
> Foil diameter
x.xx mm
Setting range: 25.4 to 50.0 mm; Unit interval: 0.1 mm;
Default setting: 25.4 mm
Foil warn stop
9864
9844
9854
Disabled
(Default setting) Printer does not stop at Foil end warning.
Enabled
If a Foil end warning occurs, the printer stops after the current label and you
see
« Press Online to acknowledge the message, then press Feed to continue
printing.
Display mode
9864
¯
9864: Dispenser version only.
Displays the number of labels printed vs. the number of labels left to print.
Job rest quant.
Displays the number of labels left to print.
¯
The counter keeps its value after turning off the printer.
Dispense counter
Counts start pulses. Select Dispense counter to enable. The counted number
appears on the display after the parameter Dispense counter (see next) is
selected.
ONLINE X JOBS
…to…
FOIL X JOBS
…while the display is blinking.
PrintStatus: 5110
Foil low