beautypg.com

System parameters, Foil end warning, Foil warn stop – Avery Dennison Monarch 9864 Info Printouts and Parameters User Manual

Page 52: Display mode

background image

06/08 Rev. AB

USER MANUAL

Info-Printouts & Parameters

9844 - 9854 - 9864

52

SYSTEM PARAMETERS

Foil end warning

9864

9844

9854

Sets the minimum ribbon roll to indicate “out of ribbon” when the value is
reached.

9864:
This message displays and a signal is set at the (optional) USI.

P

See parameters

DP INTERFACE > Ribbon signal

and

SERVICE DATA > OPERATION DATA

> Foil diameter

x.xx mm

Setting range: 25.4 to 50.0 mm; Unit interval: 0.1 mm;
Default setting: 25.4 mm

Foil warn stop

9864

9844

9854

Disabled

(Default setting) Printer does not stop at Foil end warning.

Enabled

If a Foil end warning occurs, the printer stops after the current label and you
see

« Press Online to acknowledge the message, then press Feed to continue

printing.

Display mode

9864

¯

9864: Dispenser version only.

Displays the number of labels printed vs. the number of labels left to print.

Job rest quant.

Displays the number of labels left to print.

¯

The counter keeps its value after turning off the printer.

Dispense counter

Counts start pulses. Select Dispense counter to enable. The counted number
appears on the display after the parameter Dispense counter (see next) is
selected.

ONLINE X JOBS

…to…

FOIL X JOBS

…while the display is blinking.

PrintStatus: 5110
Foil low