Application mode
9864
¯
Only with Applicator Interface.
Defines when the application process starts applying (After start signal) or
printing the label. A print job must be loaded and the printer set in online
mode.
After print
The start signal triggers the immediate printing, dispensing and applying of a
label.
After start sig.
The start signal triggers the application of a printed and dispensed label.
After applying the label, the next one is immediately printed and dispensed.
Start error stop
9864
¯
Only with Applicator Interface.
Sets how the applicator responds to a product start error. A product start error
occurs
•
If another start signal arrives before the current label is completely printed.
•
If a reprint is requested, before the first label is printed.
•
If a start signal arrives and no print job is loaded.
On
The applicator stops for a start error (default setting).
Off
Start errors are ignored.
APSF sensor res.
9864
¯
Only with Applicator Interface.
APSF sensor resolution.
This parameter is not supported.
Startdelay
9864
¯
Only with Applicator Interface.
This parameter sets the distance between the product sensor (photoelectric
switch) and the dispensing edge. The delay time is calculated from the Start
delay distance and the conveyor speed (print speed when using direct
application).
xxx.x mm
Setting range: 0.0 to 999.9 mm; Unit interval: 0.1 mm; Default setting: 0 mm