beautypg.com

Dispensposition – Avery Dennison Monarch 9864 Info Printouts and Parameters User Manual

Page 31

background image

06/08 Rev. AB

USER MANUAL

Info-Printouts & Parameters

9844 - 9854 - 9864

31

Dispensposition

¯

9864: Dispenser version only.

Dispense position

Adjusts the dispense (peel) position in or out against the feed direction.
Labels stick to more or less of the backing paper based on the setting
(Fig. 11).

[12] Dispense position (stop position) of the dispensed label.

x.x mm

Setting range: -30.0 to +20.0 mm; Unit interval: 0.1 mm; Default
setting: depends on the setting of the parameter

SYSTEM PARAMETERS >

Application mode

(see [6]).

The default setting takes effect in one of the following cases:

Factory settings

P

See parameter

SPECIALFUNCTION > Factory settings

.

Alteration of the parameter setting for Application mode.

Dispensed label

Dispense position

Dispensing edge

Backing paper

Z0040E

.cdr

Application mode

Default setting

LTS 80/400

0.0 mm

LTS 80/200

0.0 mm

manual

-6.0 mm

[6]

Different default settings, depending on the value of parameter Application mode.