Temp. reduction, Voltage offset, Expand logo – Avery Dennison Monarch 9864 Info Printouts and Parameters User Manual
Page 61

06/08 Rev. AB
USER MANUAL
Info-Printouts & Parameters
9844 - 9854 - 9864
61
6. Press Online. You see the set value.
7. Use Feed and Cut to set the previously noted resistance value of the
printhead.
8. Press Online to confirm the set value.
9. Press Prog to return to OFFLINE 0 JOBS.
Temp. reduction
9864
9844
9854
Reduction in the printhead temperature
The parameter
SYSTEM PARAMETER > Temperature reduct.
reduces the power supply
when the printhead temperature increases, thereby ensuring an even print
image.
xx%
Setting range: 0 to 50%; Unit interval: 10%
The following settings are available:
•
0%: No temperature reduction (default).
•
xx%: Up to xx% temperature reduction with a hot printhead.
P
See the User Manual, “Printing with Temperature Compensation” section for
more information.
Voltage offset
9864
9844
9854
The voltage offset increases the head voltage and, therefore, the head
temperature which was set by Easy Plug command (HV).
xx%
Setting range: 0 to 20%; Unit interval: 1%
Default setting: 0%
Expand Logo
9864
¯
Only with 8-Dot emulation.
Off
Logos are printed in normal size.
On
Logos are printed enlarged.