Receive test – Avery Dennison Monarch 9864 Info Printouts and Parameters User Manual
Page 106

06/08 Rev. AB
USER MANUAL
Info-Printouts & Parameters
9844 - 9854 - 9864
106
Receive test
9864
9844
9854
Use this test to see if the printer can receive data serially or with the parallel
port.
•
Serial connection:
The printer must be connected to the host; the parameter
INTERF.PARAM. >
Interface
must be set on RS232 or RS485.
1. Start MS-DOS.
2. Set the transmission parameters used by the printer with the MS-DOS
Command Mode.
Example of printer settings:
– Baud rate: 19200
– Data bits: 8
– Parity: none
– Stop Bits: 1
– Data synch.: RTS/CTS
DOS-Command: mode com2 19200 8 n 1
(if com2 is the serial port)
3. Press Online to start the receive test.
4. Send any file to the printer, for example:
copy anyfile.txt com2
You see:
xxxxxx is the size of the sent file in bytes. This value is calculated during the
test. The test is complete when the file size at the printer matches the size
visible in the MS-DOS window. Otherwise, transmission errors occurred.
•
Parallel connection:
The parallel connection must be set to Centronics in the parameter
INTERF.PARAM. > Interface
.
1. Call the parameter
SERVICE FUNCTION > Receive test
and press Online.
2. Start MS-DOS.
Receive test
0 Bytes
Receive test
xxxxx Bytes
Receive test
0 Bytes