[11] The size of the non-printable area in Normal 1:1 depends of the setting of parameter

"SYSTEM PARAMETERS > Dispense Position".

Batch Mode

The printer can print the entire label surface.

The label is dispensed during printing. The next label prints after the previous
label is removed.

The output volume is at the maximum.

¯

The Batch mode is optimized for printing and dispensing at high speeds.

It is not possible to use all features available in modes Normal 1:1 or Real 1:1.

¯

Do not use the following Job/Parameter combinations:

Jobs with counter fields

Jobs with variable fields

SYSTEM PARAMETER > Dispensing mode

must be set to fast.

The USI reprint function is not supported.

DP INTERFACE > Reprint signal

must be

set to deactivated.

Foil save

P

A graphic can be found under

PRINT PARAMETERS > Cut mode > Batch mode

.

Real 1:1 Mode

(Default setting)

The printer can print the entire label surface.

After dispensing a label, the beginning of the next label is backed up under
the printhead.

The output volume is lower than in Batch Mode or Normal 1:1 Mode.

P

A graphic can be found under

PRINT PARAMETERS > Cut mode > Real 1:1 mode

.

a

b

c

Label

Backing paper

Printing

Printhead

Dispensing
Edge

Feed
Direction

Non-printable area with

Dispense

Dispense

a) Dispense position = 0
b)

position < 0

c)

position > 0