Altera Mentor Verification IP Altera Edition AMBA AXI3/4TM User Manual
Page 694

Mentor VIP AE AXI3/4 User Guide, V10.2b
674
Assertions
AXI3 Assertions
September 2013
Error
Code
Error Name
Description
Property
Ref
AXI3-
60130
AXI_WRITE_DATA_UNKN_ON_
INVALID_LANE
On a lane whose strobe is 0, WDATA has an
X or Z value.
A2.3
AXI3-
60131
AXI_WRITE_DATA_UNKN_ON_
VALID_LANE
On a lane whose strobe is 1, WDATA has an
X or Z value.
A2.3
AXI3-
60132
AXI_RESERVED_AWLOCK_
ENCODING
The reserved encoding of 2'b11 should not
be used for AWLOCK.
A7.4
AXI3-
60133
AXI_WRITE_STROBE_ON_INVALID_
BYTE_LANES
Write strobe(s) incorrect for the address/size
of a fixed transfer.
A2.3
AXI3-
60134
AXI_WSTRB_CHANGED_BEFORE_
WREADY
The value of WSTRB has changed from its
initial value between the time WVALID was
asserted, and before WREADY was
asserted.
A3.2.1
AXI3-
60135
AXI_WSTRB_UNKN
WSTRB has an X or Z value.
A2.3
AXI3-
60136
AXI_WUSER_CHANGED_BEFORE_
WREADY
The value of WUSER has changed from its
initial value between the time WVALID was
asserted, and before WREADY was
asserted.
A3.2.1
AXI3-
60137
AXI_WUSER_UNKN
WUSER has an X or Z value.
A2.3
AXI3-
60138
AXI_WVALID_DEASSERTED_
BEFORE_WREADY
WVALID has been de-asserted before
WREADY was asserted.
A3.2.1
AXI3-
60139
AXI_WVALID_HIGH_ON_FIRST_
CLOCK_AFTER_RESET
A master interface must begin driving
WVALID high only at a rising clock edge after
ARESETn is HIGH.
A3.1.2
AXI3-
60140
AXI_WVALID_UNKN
WVALID has an X or Z value.
A2.3
AXI3-
60141
AXI_ADDR_ACROSS_4K_WITHIN_
LOCKED_WRITE_TRANSACTION
Transactions in a locked write sequence
should be in the same 4K address boundary.
A7.3
AXI3-
60142
AXI_ADDR_ACROSS_4K_WITHIN_
LOCKED_READ_TRANSACTION
Transactions in a locked read sequence
should be in the same 4K address boundary.
A7.3
AXI3-
60143
AXI_AWID_CHANGED_WITHIN_
LOCKED_TRANSACTION
Master should not change the AWID signal in
the locked transaction.
A7.3
AXI3-
60144
AXI_ARID_CHANGED_WITHIN_
LOCKED_TRANSACTION
Master should not change the ARID signal in
the locked transaction.
A7.3
AXI3-
60145
AXI_AWPROT_CHANGED_WITHIN_
LOCKED_TRANSACTION
Master should not change the AWPROT
signal in the locked transaction.
A7.3
Table A-1. AXI3 Assertions (cont.)