Execute_read_data_ready(), Axi3 bfm, Axi4 example – Altera Mentor Verification IP Altera Edition AMBA AXI3/4TM User Manual
Page 349

VHDL AXI3 and AXI4 Master BFMs
execute_read_data_ready()
Mentor VIP AE AXI3/4 User Guide, V10.2b
331
September 2013
execute_read_data_ready()
This AXI4 procedure executes a read data ready by placing the ready argument value onto the
RREADY signal. It will block (default) for one ACLK period.
AXI3 BFM
Note
The execute_read_data_ready() task is not available in the AXI3 BFM. Use the
task along with the transaction record data_ready_delay field.
AXI4 Example
-- Set the RREADY signal to 1 and block for 1 ACLK cycle
execute_read_data_ready(1, 1, index, AXI4_PATH_6, axi4_tr_if_6(index));
Prototype
procedure execute_read_data_ready
(
ready : in integer
non_blocking_mode : in integer; --optional
bfm_id : in integer;
path_id : in axi4_path_t; --optional
signal tr_if : inout axi4_vhd_if_struct_t
);
Arguments
ready
The value to be placed onto the RREADY signal
non_blocking_mode (Optional) Nonblocking mode:
0 = Nonblocking
1 = Blocking (default)
bfm_id
BFM identifier. Refer to
on page 203 for more details.
path_id
(Optional) Parallel process path identifier:
AXI4_PATH_0
AXI4_PATH_1
AXI4_PATH_2
AXI4_PATH_3
AXI4_PATH_4
Refer to
“Overloaded Procedure Common Arguments”
page 203 for more details.
tr_if
Transaction signal interface. Refer to
on page 203 for more details.
Returns
None