beautypg.com

Installation, General requirements, 5installation – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 97: 1 general requirements

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

5-1

5.1

General requirements

5

Installation

5

5000

Installation

Installation

5-

5.1

General requirements

5100

General requirements

5-

][Montage_Einbauort

Mounting location

`

The servo amplifier should be installed in an enclosure, e.g. control

cabinet, that conforms to the protection class required for the envi-

ronment.

`

The mounting location must be free from conductive and aggressive

materials.

`

Make sure you keep the necessary space clear above and below the

servo amplifier (see section entitled “Installing the servo amplifier”)

][Montage_Umgebung

Environmental conditions

`

When installing the system in an enclosure such as a control cabinet,

the environmental data for the servo amplifier must be taken into ac-

count. Details can be found in the chapter entitled “Technical Details”.

`

Protect the servo amplifier from undue stress. In particular, do not al-

low any components to become bent and/or insulation distances to

be modified during transportation and handling.

`

Make sure there is an adequate flow of cool, filtered air from the bot-

tom of the control cabinet or use a heat exchanger. Please note the

ambient temperature of 0 - 40 °C with nominal data, 40 - 55 °C with

power derating 2.5 %/K.

`

In extreme ambient conditions, additional measures may be required

in order to keep within the prescribed value range.

][Montage_Erdung

Earthing, EMC

`

Make sure that the servo amplifier and motor are earthed correctly.

Do not use varnished (non-conductive) mounting plates.

`

Components that generate magnetic fields should not be installed di-

rectly next to the servo amplifier. If necessary, shield the magnetic

fields.

][Montage_Entladung

`

Damage due to electrostatic discharge!

Electrostatic discharge can damage components. Ensure discharge

before touching the servo amplifier, e.g. by touching an earthed, con-

ductive surface or by wearing an earthed armband.

][Montage_Netzteil

Power supply

`

The servo amplifier and power supply should be installed close to

each other on the conductive, earthed mounting plate inside the con-

trol cabinet.

][Montage_Schaltschrankbeleuchtung

Control cabinet lighting

`

Use low interference panel lighting for inside the control cabinet.

This manual is related to the following products: