Installation, General requirements, 5installation – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual
Page 97: 1 general requirements
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
5-1
5.1
General requirements
5
Installation
5
5000
Installation
Installation
5-
5.1
General requirements
5100
General requirements
5-
][Montage_Einbauort
Mounting location
`
The servo amplifier should be installed in an enclosure, e.g. control
cabinet, that conforms to the protection class required for the envi-
ronment.
`
The mounting location must be free from conductive and aggressive
materials.
`
Make sure you keep the necessary space clear above and below the
servo amplifier (see section entitled “Installing the servo amplifier”)
][Montage_Umgebung
Environmental conditions
`
When installing the system in an enclosure such as a control cabinet,
the environmental data for the servo amplifier must be taken into ac-
count. Details can be found in the chapter entitled “Technical Details”.
`
Protect the servo amplifier from undue stress. In particular, do not al-
low any components to become bent and/or insulation distances to
be modified during transportation and handling.
`
Make sure there is an adequate flow of cool, filtered air from the bot-
tom of the control cabinet or use a heat exchanger. Please note the
ambient temperature of 0 - 40 °C with nominal data, 40 - 55 °C with
power derating 2.5 %/K.
`
In extreme ambient conditions, additional measures may be required
in order to keep within the prescribed value range.
][Montage_Erdung
Earthing, EMC
`
Make sure that the servo amplifier and motor are earthed correctly.
Do not use varnished (non-conductive) mounting plates.
`
Components that generate magnetic fields should not be installed di-
rectly next to the servo amplifier. If necessary, shield the magnetic
fields.
][Montage_Entladung
`
Damage due to electrostatic discharge!
Electrostatic discharge can damage components. Ensure discharge
before touching the servo amplifier, e.g. by touching an earthed, con-
ductive surface or by wearing an earthed armband.
][Montage_Netzteil
Power supply
`
The servo amplifier and power supply should be installed close to
each other on the conductive, earthed mounting plate inside the con-
trol cabinet.
][Montage_Schaltschrankbeleuchtung
Control cabinet lighting
`
Use low interference panel lighting for inside the control cabinet.
- PMCprimo DriveP.01/AA0/5/0/0/208-480VAC PMCprimo DriveP.12/AA0/4/0/0/208-480VAC PMCprimo DriveP.12/AA0/4/P/0/208-480VAC PMCprimo DriveP.03/AA0/4/0/0/208-480VAC PMCprimo DriveP.06/AA0/4/0/0/208-480VAC PMCprimo DriveP.24/ABB/4/0/0/208-480VAC PMCprimo DriveP.03/AB0/5/0/0/208-480VAC PMCprimo DriveP.06/AB0/2/0/0/208-480VAC PMCprimo DriveP.03/AB0/3/0/0/208-480VAC PMCprimo DriveP.06/AB0/3/0/0/208-480VAC PMCprimo DriveP.12/AB0/2/0/0/208-480VAC PMCprimo DriveP.12/ABC/4/P/0/208-480VAC PMCprimo DriveP.12/AB0/3/0/0/208-480VAC PMCprimo DriveP.03/AB0/2/0/0/208-480VAC PMCprimo DriveP.12/AAC/4/0/0/208-480VAC PMCprimo DriveP.24/AA0/5/0/0/208-480VAC PMCprimo DriveP.12/AA0/2/0/0/208-480VAC PMCprotego D.01/000/0/0/2/208-480VAC PMCprotego D.03/000/0/0/2/208-480VAC PMCprotego D.06/000/0/0/2/208-480VAC PMCprotego D.12/000/0/0/2/208-480VAC PMCprotego D.24/000/0/0/2/208-480VAC PMCprotego D.12/000/0/P/2/208-480VAC PMCprotego D.24/000/0/P/2/208-480VAC PMCprotego D.01/200/0/0/2/208-480VAC PMCprotego D.01/100/0/0/2/208-480VAC PMCprotego D.01/010/0/0/2/208-480VAC PMCprotego D.06/010/0/0/2/208-480VAC PMCprotego D.06/100/0/0/2/208-480VAC PMCprotego D.06/200/0/0/2/208-480VAC PMCprotego D.03/010/0/0/2/208-480VAC PMCprotego D.03/200/0/0/2/208-480VAC PMCprotego D.03/100/0/0/2/208-480VAC PMCprotego D.12/010/0/0/2/208-480VAC PMCprotego D.24/200/0/P/2/208-480VAC PMCprotego D.12/200/0/0/2/208-480VAC PMCprotego D.12/100/0/0/2/208-480VAC PMCprotego D.12/010/0/P/2/208-480VAC PMCprotego D.12/200/0/P/2/208-480VAC PMCprotego D.24/100/0/P/2/208-480VAC PMCprotego D.24/010/0/P/2/208-480VAC PMCprotego D.12/100/0/P/2/208-480VAC PMCprotego D.24/200/0/0/2/208-480VAC PMCprotego D.24/100/0/0/2/208-480VAC PMCprotego D.24/010/0/0/2/208-480VAC