4.3

Control element

4

Function Description

4.3.2.2

Digital inputs

Digital inputs

4-

][Funktion_Ein_dig_enable_protego_D

ENABLE (X3A/1)

Functions:

`

A “1” signal enables the inverted rectifier of the servo amplifier in or-

der to drive the motor.

`

The enable is only possible if the inputs STO1-ENABLE and STO2-

ENABLE are connected for the safety function in accordance with the

application (see section: "Digital inputs STO1-ENABLE (X4B/6),

STO2-ENABLE (X4A/3)".

`

In a disabled condition (“0” signal), the connected motor is torque-

free.

`

PLC-compatible (IEC 61131-2 Type 1), volt-free, reference earth is

DGND

Further information and connection examples can be found in this chap-

ter under "Safety function STO".

Parameter setting:

`

A software enable is also required in the commissioning software (log-

ic AND connection).

`

The enable can also be permanently activated ("Basic Setup" window

in the PDrive commissioning software).

][Funktion_Ein_dig_X3_2_7_allg_protego_D

X3A/6, 7

DIGITAL-
INOUT1
DIGITAL-
INOUT2

2

Semiconductor input
or output

IEC 61131-2
Type 1

4 kHz

Signal output
from pre-pro-
grammed func-
tions

X3B/14, 15

BTO/RTO

1

Relay output

max. 30 VDC,
max. 42 VAC

Operational
readiness

X4B/6

STO1-ENABLE 1

Semiconductor input

20 - 30 V

Safety function
STO
1. shutdown
route
safe

X4A/3

STO2-ENABLE 1

Semiconductor input

20 - 30 V

Safety function
STO
2. shutdown
route
safe

Connectors/
terminals

Description

Number

Type

Signal range

Scan rate

Application