Control element

4

Function Description

Key:

`

BTB/RTO: Relay output, operational readiness

`

ENABLE: Digital input, enable signal

`

STO1-ENABLE: Digital input, 1st shutdown route for shutting down

the pulse disabler safely

`

STO2-ENABLE: Digital input, 2nd shutdown route for shutting down

the pulse disabler safely

`

STO feedback: Digital output, switch state of pulse disabler

`

T1 … T5: Test sequence

`

Start test: Start of test sequence

`

End test: End of test sequence

ENABLE = "1" can be set after the end of the test sequence.

STO2-ENABLE

X4A/3

1

0

1

0

1

0

STO1-ENABLE

X4B/6

STO-Feedback

X3A/6

t

T1

T2

T3

T4

T5

1

0

1

0

BTB/RTO

X3B/14,15

ENABLE

X3A/1

Start Test

End Test