beautypg.com

2overview, 1 unit structure – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 15

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

2-3

2.1

Unit structure

2

Overview

Operation and display

`

Servo amplifier operated via two keys

`

Three-digit LED display for status and messages

][Ueber_Merkmale_integrierte_Sicherheit

Integrated safety

`

Device safety

– Safe electrical isolation between mains voltage/motor connection

and control element, in accordance with EN 61800-5-1

– Soft start, overvoltage detection, short circuit protection, phase

failure monitoring

– Temperature monitoring of servo amplifier and motor (when using

Pilz motors with ready-made cables)

`

Protection of personnel and plant

– Safety function STO – Safe torque off

Single-channel without feedback: Up to PL d (Cat. 2) of

EN ISO 13849-1 and SIL CL 2 of EN/IEC 62061

Dual-channel with feedback: Up to PL e (Cat. 4) of EN ISO 13849-

1 and SIL CL 3 of EN/IEC 62061

– Slot for safety card: Safety functions for safe operation of drive

axes in accordance with DIN IEC 61800-5-2, up to PL e (Cat. 4) of

EN ISO 13849-1 and SIL CL 3 of EN/IEC 62061

Ueber_Merkmale_Schnittstellen_protego_D

Communications interfaces

`

CANopen interface for

– Connection to CAN bus systems

– Parameters for several drives can be set via a servo amplifier's se-

rial interface

`

RS 232 interface for parameter setting with the PDrive commissioning

software

`

2 Ethernet interfaces (in development)

][Ueber_Merkmale_SD_protego_D

SD card

`

Read/write device for SD card, for reading and writing parameters

and firmware

Ueber_Merkmale_Erweiterungen_protego_D

Expansion cards

3 slots for expansion cards

`

Expansion cards for slot 1:

– I/O-14/08

– PROFIBUS

– DeviceNet

– SERCOS

This manual is related to the following products: