4-3
4.2
Power element
4
Function Description
4.2
Power element
4200
Power element
4-
][Funktion_Leistungsteil
The power element of the servo amplifier converts the fixed voltage and
frequency of the mains into a variable voltage and frequency for driving
the motor This means that the rotational speed and torque are infinitely
variable. The power element consists of:
`
Filter A
`
Rectifier B
`
Charging circuit with intermediate circuit C
`
Brake chopper D
`
Inverted rectifier E
Fig. 4-2:
Power element
4.2.1
Mains voltage
Mains voltage
4-
][Funktion_Netzspannung_protego_D
The servo amplifier is suitable for connection to TT and TN networks.
The voltage range of the servo amplifier is 3 x 208 VAC - 3 x 480 VAC.
Please note the maximum permitted voltages between the external con-
ductors (L1, L2, L3) and the servo amplifier housing:
`
Periodic overvoltages between the external conductors and the hous-
ing: Max. 1000 V (amplitude)
`
Voltage spikes (< 50
μ
s) between the external conductors in accord-
ance with EN 61800: Max. 1000 V
`
Voltage spikes (< 50
μ
s) between the external conductors and the
housing: Max. 2000 V
Direct connection to PMCprotego D
`
208 – 240 V mains supplies without earthed star point (asymmetrically
earthed or unearthed mains supplies), see Fig. (2) – (6)
`
208 – 480 V mains supplies with earthed star point, see Figure (1)
Connection via isolating transformer
`
400 – 480 V mains supplies without earthed star point (asymmetrically
earthed or unearthed mains supplies), see Fig. (7) – (11)
A
C
E
3
B
D
- PMCprimo DriveP.01/AA0/5/0/0/208-480VAC PMCprimo DriveP.12/AA0/4/0/0/208-480VAC PMCprimo DriveP.12/AA0/4/P/0/208-480VAC PMCprimo DriveP.03/AA0/4/0/0/208-480VAC PMCprimo DriveP.06/AA0/4/0/0/208-480VAC PMCprimo DriveP.24/ABB/4/0/0/208-480VAC PMCprimo DriveP.03/AB0/5/0/0/208-480VAC PMCprimo DriveP.06/AB0/2/0/0/208-480VAC PMCprimo DriveP.03/AB0/3/0/0/208-480VAC PMCprimo DriveP.06/AB0/3/0/0/208-480VAC PMCprimo DriveP.12/AB0/2/0/0/208-480VAC PMCprimo DriveP.12/ABC/4/P/0/208-480VAC PMCprimo DriveP.12/AB0/3/0/0/208-480VAC PMCprimo DriveP.03/AB0/2/0/0/208-480VAC PMCprimo DriveP.12/AAC/4/0/0/208-480VAC PMCprimo DriveP.24/AA0/5/0/0/208-480VAC PMCprimo DriveP.12/AA0/2/0/0/208-480VAC PMCprotego D.01/000/0/0/2/208-480VAC PMCprotego D.03/000/0/0/2/208-480VAC PMCprotego D.06/000/0/0/2/208-480VAC PMCprotego D.12/000/0/0/2/208-480VAC PMCprotego D.24/000/0/0/2/208-480VAC PMCprotego D.12/000/0/P/2/208-480VAC PMCprotego D.24/000/0/P/2/208-480VAC PMCprotego D.01/200/0/0/2/208-480VAC PMCprotego D.01/100/0/0/2/208-480VAC PMCprotego D.01/010/0/0/2/208-480VAC PMCprotego D.06/010/0/0/2/208-480VAC PMCprotego D.06/100/0/0/2/208-480VAC PMCprotego D.06/200/0/0/2/208-480VAC PMCprotego D.03/010/0/0/2/208-480VAC PMCprotego D.03/200/0/0/2/208-480VAC PMCprotego D.03/100/0/0/2/208-480VAC PMCprotego D.12/010/0/0/2/208-480VAC PMCprotego D.24/200/0/P/2/208-480VAC PMCprotego D.12/200/0/0/2/208-480VAC PMCprotego D.12/100/0/0/2/208-480VAC PMCprotego D.12/010/0/P/2/208-480VAC PMCprotego D.12/200/0/P/2/208-480VAC PMCprotego D.24/100/0/P/2/208-480VAC PMCprotego D.24/010/0/P/2/208-480VAC PMCprotego D.12/100/0/P/2/208-480VAC PMCprotego D.24/200/0/0/2/208-480VAC PMCprotego D.24/100/0/0/2/208-480VAC PMCprotego D.24/010/0/0/2/208-480VAC