beautypg.com

6wiring, 7 control element – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 129

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-25

6.7

Control element

6

Wiring

Connection

Output circuit

Digital output

24 VDC

Referenced to earth: Always con-
nect DGND (X3B/16) to I/O-GND
on the control system

Pin 6 and 7 must be configured as
a digital output in the commission-
ing software

Relay contact for operational read-
iness, servo amplifier

DI 2

6

7

8

DGND

PMCprotego

24 V

I/O-GND

X3A

DIGITAL-INOUT1

DIGITAL-INOUT2

X3B

16

DI 1

24 V

I 2

14

15

PMCprotego

X3B

BTB/RTO

I 1

BTB/RTO

This manual is related to the following products: