4.3

Control element

4

Function Description

Parameter setting:

4.3.6

Electronic gearing, Master-Slave mode

Electronic gearing, Master-Slave mode

4-

][Funktion_Getriebe_elektronisch_protego_D

Functions:

`

With electronic gearing, multiple axes are synchronised through soft-

ware in the servo amplifier.

`

The servo amplifier is controlled as a slave by an external, secondary

encoder.

`

You can build up master/slave systems or use an external encoder as

a setpoint encoder.

Parameter setting:

`

Parameters for the servo amplifier are set using the commissioning

software (electronic gearing):

– Number of pulses and revolutions

– Reduction and transmission gear ratios

The following types may be used as external encoders for the reference

signal:

Encoder type

Parameter FBTYPE

Parameter EXTPOS

Parameter GEAR-
MODE

Absolute encoder with SSI interface

25

25

25

INFORMATION

If you are not using the supply voltage at X1 and are connecting

the encoders to the X1 terminal, please note:

`

Change Bit 20 of the ASCII command DRVCNFG2 (see ASCII

Object Reference in the commissioning software's online

help), otherwise error F04 will be registered.

Encoder type

Connector

Parameter
GEARMODE

SinCos encoder with BISS digital interface

X1

11, 12

SinCos encoder with EnDat 2.1 interface

X1

8

SinCos encoder with EnDat 2.2 interface

X1

13

SinCos encoder with HIPERFACE interface

X1

9

SinCos encoder without data track

X1

6, 7

Incremental encoder (AquadB) 5 V, 350 kHz

X1

10

Incremental encoder (AquadB) 5 V, 1.5 MHz

X1

30