Power element

6

Wiring

Use the following fuses for F

B1

and F

B2

, depending on the device type.

US types in brackets

6.6.4

Intermediate circuit

Intermediate circuit

6-

][Verdr_Leiterquerschnitte_Verweis

Under “Connection cables”, please note the requirements for the:

`

Cable cross sections

`

Insulation material

][Verdr_Zwischenkreis_protego_D

The connections for the intermediate circuit are

`

not short circuit and earth fault proof

`

Not reverse polarity protected.

][Funktion_Zwischenkreis_Wichtig

Fuse

Device type

01, 03

06

12

24

Blow-out fuse or similar

6 AT
(FRS-6)

10 AT
(FRS-10)

16 AT
(FRS-16)

25 AT
(FRS-25)

Connector pin assignment

Connector X8

Pin

Designation

Description

1

-DC

Intermediate circuit voltage -DC

2

+Rbe/+DC

Intermediate circuit voltage +DC

Connection

Output/input circuit

Intermediate circuit

Cable runs

200 mm:

Use unshielded single wires
(2.5 mm²)

Cable runs > 200 mm:
Use shielded cables.

X8

-DC 1

+RBe 2

+RBi 3

-RB 4

1

RBe/+DC

2

PMCprotego

X8

-DC

PMCprotego

X8

1

2

PMCprotego

RBe/+DC

-DC

This manual is related to the following products: