beautypg.com

4function description, 4 expansion cards – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 81

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

4-49

4.4

Expansion cards

4

Function Description

Setting the station address

The drive address can be set between 0 and 63.

The drive is assigned as an amplifier in the SERCOS ring with address =

0.

There are two ways of setting the station address:

`

Using the keys on the front of the servo amplifier (see section entitled

“LEDs and keys” in the “Commissioning” chapter).

`

Using the commissioning software, in the “CAN/Fieldbus” window.

Alternatively you can go to the “Terminal” window in the commission-

ing software and enter the: ADDR # command, where # is the drive's

new address.

Set the transmission rate and optical output

Change the transmission rate:

`

Communication is impossible if the transmission rate is set incorrect-

ly.

`

The transmission rate is set in the commissioning software using the

SBAUD # parameter. # is the transmission rate in MBit/s.

Change the optical output:

`

Errors will occur in the telegram transmission if the optical output is

set incorrectly. The ERR LED will light.

`

When communication is running normally, the RT and TT LEDs will

light.

`

The optical range for a standard 1 mm² glass fibre cable is defined in

the commissioning software via the SLEN # parameter. # is the length

of the cable in metres.

SBAUD

SLEN

2

2 MBit/s

0

Very short connection

4

4 MBit/s

1…< 15

Length of the connection
with a 1 mm² plastic cable

8

8 MBit/s

15…< 30

Length of the connection
with a 1 mm² plastic cable

16

16 MBit/s

30

Length of the connection
with a 1 mm² plastic cable