beautypg.com

4 analogue inputs, 6wiring, 7 control element – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 130

background image

6.7

Control element

6

Wiring

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-26

6.7.4

Analogue inputs

Analogue inputs

6-

][Verdr_Leiterquerschnitte_Verweis

Under “Connection cables”, please note the requirements for the:

`

Cable cross sections

`

Insulation material

][Verdr_AI_protego_D

Connector pin assignment

Connector X3A/X3B

Pin

Designation

Description

9

ANALOG-IN1-

Analogue input 1-

10

ANALOG-IN1-

Analogue input 1+

11

ANALOG-IN2-

Analogue input 2-

12

ANALOG-IN2+

Analogue input 2+

13

AGND

Reference earth for analogue inputs

Connection

Input circuit

Analogue input

- Signal range –10 ... +10 V
- Referenced to earth: Always con-
nect AGND (X3B/13) to CNC-GND
on the control system
- Twisted pair, shielded
- Shield connection on the front plate

X3A

1

2

3

4

X3B

5

6

7

8

9

10

12

13

14

15

16

11

+O1

9

ANALOG-IN1-

10

11

12

AGND

13

PMCprotego

-O1

+/- 10 V

+O2

-O2

+/- 10 V

CNC-GND

GND

X3B

Shield

ANALOG-IN1+

ANALOG-IN2-

ANALOG-IN2+

This manual is related to the following products: