beautypg.com

Power element, 1 mains voltage, 6wiring – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 119: 6 power element

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-15

6.6

Power element

6

Wiring

6.6

Power element

6600

Power element

6-

6.6.1

Mains voltage

Mains voltage

6-

][Verdr_Leiterquerschnitte_Verweis

Under “Connection cables”, please note the requirements for the:

`

Cable cross sections

`

Insulation material

][Verdr_Netz_protego_D

Please note the following important points under “Mains voltage”, in the

chapter entitled “Function Description”:

`

The mains voltage requirements (network configurations)

`

The use of isolating transformers

Connector pin assignment

Connector X0

Pin

Designation

Description

1

PE

Earth conductor

2

L3

Mains voltage phase L3

3

L2

Mains voltage phase L2

4

L1

Mains voltage phase L1

Connection

Mains voltage for power element

Three-phase

X0

1 PE

2 L3

3 L2
4 L1

1

L3

2

3

4

PMCprotego

X0

L1

L2

PE

L3

L1

L2

PE

FN3

FN1

FN2

This manual is related to the following products: