Wiring procedure, 6wiring, 4 wiring procedure – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual
Page 114

6.4
Wiring procedure
6
Wiring
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
6-10
6.4
Wiring procedure
6400
Wiring procedure
6-
][Verdr_Vorgehensweise
The following guidelines are intended to help you carry out the electrical
installation in a sensible order, without forgetting anything important.
Choice of cable
`
Select cables in accordance with EN 60204
Earthing, shielding
`
Make sure that shielding and earthing are EMC-compliant
`
Earth the mounting plate, the motor housing and the control system's
ground terminal. Information on the connection technology can be
found under “Block diagram”.
Wiring
`
Lay the power and control cables separately
`
Incorporate the relay output for operational readiness (BTB) into the
plant's safety circuit
`
Connect the servo amplifier's digital inputs and outputs
`
Connect the AGND earth (even if a fieldbus is used)
`
If necessary, connect the analogue setpoint value
`
Connect the encoder (feedback)
`
Connect the expansion card
`
Connect the motor cables
`
Connect the shielding on both ends; use a motor choke if the cable
runs are over 25 m
`
Connect the motor holding brake, connect the shielding on both ends
`
If necessary, connect the external brake resistor (with fuse protection)
`
Connect the 24 VDC supply voltage (for maximum permitted voltage
values see chapter entitled “Technical Details”)
`
Connect the mains voltage (for maximum permitted voltage values
see chapter entitled “Technical Details”); for information on FI residual
current devices see section entitled “Residual current devices”)
`
Connect the PC (see section entitled “Communications interfaces”)
Check
`
Check the wiring against the wiring diagrams
- PMCprimo DriveP.01/AA0/5/0/0/208-480VAC PMCprimo DriveP.12/AA0/4/0/0/208-480VAC PMCprimo DriveP.12/AA0/4/P/0/208-480VAC PMCprimo DriveP.03/AA0/4/0/0/208-480VAC PMCprimo DriveP.06/AA0/4/0/0/208-480VAC PMCprimo DriveP.24/ABB/4/0/0/208-480VAC PMCprimo DriveP.03/AB0/5/0/0/208-480VAC PMCprimo DriveP.06/AB0/2/0/0/208-480VAC PMCprimo DriveP.03/AB0/3/0/0/208-480VAC PMCprimo DriveP.06/AB0/3/0/0/208-480VAC PMCprimo DriveP.12/AB0/2/0/0/208-480VAC PMCprimo DriveP.12/ABC/4/P/0/208-480VAC PMCprimo DriveP.12/AB0/3/0/0/208-480VAC PMCprimo DriveP.03/AB0/2/0/0/208-480VAC PMCprimo DriveP.12/AAC/4/0/0/208-480VAC PMCprimo DriveP.24/AA0/5/0/0/208-480VAC PMCprimo DriveP.12/AA0/2/0/0/208-480VAC PMCprotego D.01/000/0/0/2/208-480VAC PMCprotego D.03/000/0/0/2/208-480VAC PMCprotego D.06/000/0/0/2/208-480VAC PMCprotego D.12/000/0/0/2/208-480VAC PMCprotego D.24/000/0/0/2/208-480VAC PMCprotego D.12/000/0/P/2/208-480VAC PMCprotego D.24/000/0/P/2/208-480VAC PMCprotego D.01/200/0/0/2/208-480VAC PMCprotego D.01/100/0/0/2/208-480VAC PMCprotego D.01/010/0/0/2/208-480VAC PMCprotego D.06/010/0/0/2/208-480VAC PMCprotego D.06/100/0/0/2/208-480VAC PMCprotego D.06/200/0/0/2/208-480VAC PMCprotego D.03/010/0/0/2/208-480VAC PMCprotego D.03/200/0/0/2/208-480VAC PMCprotego D.03/100/0/0/2/208-480VAC PMCprotego D.12/010/0/0/2/208-480VAC PMCprotego D.24/200/0/P/2/208-480VAC PMCprotego D.12/200/0/0/2/208-480VAC PMCprotego D.12/100/0/0/2/208-480VAC PMCprotego D.12/010/0/P/2/208-480VAC PMCprotego D.12/200/0/P/2/208-480VAC PMCprotego D.24/100/0/P/2/208-480VAC PMCprotego D.24/010/0/P/2/208-480VAC PMCprotego D.12/100/0/P/2/208-480VAC PMCprotego D.24/200/0/0/2/208-480VAC PMCprotego D.24/100/0/0/2/208-480VAC PMCprotego D.24/010/0/0/2/208-480VAC