beautypg.com

4 expansion card with profibus-dp interface, 6wiring, 8 expansion cards – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 168

background image

6.8

Expansion cards

6

Wiring

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-64

6.8.4

Expansion card with PROFIBUS-DP interface

Expansion card with PROFIBUS-DP interface

6-

][Verdr_PROFIBUS_protego_D

Please note:

You will need the expansion card PROFIBUS-DP. The expansion card is

in slot 1.

Connector pin assignment

Connector X12A/X12B

Pin

Designation

Description

1

n. c.

--

2

n. c.

--

3

RxD/TxD-P

B-line

4

n. c.

--

5

GND

Earth

6

VP

Supply voltage +5 VDC

7

n. c.

--

8

RxD/TxD-N

A-line

n. c. = not connected

Connection

Interface

PROFIBUS-DP

Shielded cable
Shield connection in the connector

INFORMATION

Cable selection, cable routing, shielding, bus connectors, bus

termination and runtimes are all described in the “PROFIBUS-

DP/FMS Installation Guidelines” published by the PROFIBUS

User Group PNO.

1

5

6

9

1

4

6

PMCprotego

PLC

3

A (RxD/TxD-N)

GND

VP

390 W

390 W

390 W

220 W

220 W

390 W

5

8

1

4

6

3

5

8

B (RxD/TxD-P)

A (RxD/TxD-N)

GND

VP

B (RxD/TxD-P)

X12A

X12B