beautypg.com

3 analogue outputs, 4 analogue inputs, 4 expansion card with profibus-dp interface – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 79: 4function description, 4 expansion cards

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

4-47

4.4

Expansion cards

4

Function Description

4.4.3.3

Analogue outputs

Analogue outputs

4-

][Funktion_Erw_PosI_O_AO

Functions:

`

The expansion card PosI/O-AIO has 2 analogue voltage outputs (AN-

ALOG-OUT1, ANALOG-OUT2). Digital measured values recorded in

the servo amplifier can be output.

`

Signal range from -10 VDC to +10 VDC.

`

Resolution (with sign bit): 16 Bit

Parameter setting:

`

A list of the pre-programmed functions is available in the “Digital I/O”

window of the PDrive commissioning software.

][Funktion_Ein_Aus_Param_neu

`

If a pre-programmed function has been newly assigned, the data

record must be stored in the servo amplifier's EEPROM and the unit

must be reset (e.g. using the commissioning software).

4.4.3.4

Analogue inputs

Analogue inputs

4-

][Funktion_Erw_PosI_O_AI

Functions:

`

The expansion card PosI/O-AIO has 2 analogue voltage inputs (ANA-

LOG-IN3, ANALOG-IN4) for specifying setpoint values.

`

Differential inputs, signal range from -10 VDC to +10 VDC.

`

Resolution (with sign bit): 16 Bit

Parameter setting:

`

A list of the pre-programmed functions is available in the “Digital I/O”

window of the PDrive commissioning software.

][Funktion_Ein_Aus_Param_neu

`

If a pre-programmed function has been newly assigned, the data

record must be stored in the servo amplifier's EEPROM and the unit

must be reset (e.g. using the commissioning software).

4.4.4

Expansion card with PROFIBUS-DP interface

Expansion card with PROFIBUS-DP interface

4-

][Funktion_Erw_PROFIBUS_protego_D

The PROFIBUS-DP expansion card is available as an accessory.

Information on the functionality and software protocol can be found in

the “Communication profile” manual.

The expansion card has two PROFIBUS-DP interfaces. They are wired

in parallel on two female 9-pin D-Sub connectors.

The servo amplifier supplies the voltage to the expansion card.