beautypg.com

7 connection example for sto, dual-channel, 4function description, 3 control element – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 53

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

4-21

4.3

Control element

4

Function Description

`

Shorts across contacts are detected.

`

The safety relay is wired for an automatic reset.

`

The safety function STO complies with PL d (Cat. 2) of EN ISO 13849-

1 and SIL CL 2 of EN/IEC 62061.

The relays' wiring must comply with the category or performance level

required for the application. Further information on the safety relays is

available from Pilz.

Fig. 4-7:

STO, single-channel with safety relay PNOZ S3

4.3.3.7

Connection example for STO, dual-channel

Connection example for STO, dual-channel

4-

][Funktion_STO_Beispiel_zweikanalig

The following circuit example illustrates dual-channel activation of the

safety function STO.

`

Activation of the inputs STO1-ENABLE and STO2-ENABLE is dual-

channel, via the semiconductor outputs from a safety control system

PNOZ mm0p.

`

During the periodic test, the state of the pulse disabler is evaluated

with the feedback signal DIGITAL-INOUT1.

`

The safety function STO complies with PL e (Cat. 4) of EN ISO 13849-

1 and SIL CL 3 of EN/IEC 62061.

The relays' wiring must comply with the category or performance level

required for the application. Further information on the safety control

system PNOZmulti is available from Pilz.

PNOZ s3

A1 S11

STO1-ENABLE

STO2-ENABLE

S12 S21 S22 23

24

S12 S34

A2

X4A

X4B

24V

0V

24 V

0 V

S1

S2

6

3

4

5

PMCprotego D

This manual is related to the following products: