beautypg.com

4function description, 5 switch on/switch off behaviour – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 87

background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

4-55

4.5

Switch on/switch off behaviour

4

Function Description

Fig. 4-17:

Switching on and off under normal conditions

Servo amplifiers on which the “Holding brake” function has been ena-

bled have a separate procedure to switch off the inverted rectifier (see

section in this chapter entitled “Motor holding brake”).

The drive is shut down safely using the safety function STO (STO1-EN-

ABLE/STO2-ENABLE).

][Funktion_Ein_Aus_Hinweis

NOTICE

Please note the following when using a safety card PMCprotego

S: Before setting the servo amplifier enable, the "Ready" output

on the safety card (X30/16) must be polled!

24 V

X4/1

BTB/RTO

X3B/14,15

L1,L2,L3

X0

Intermediate

circuit X8

STO

HW-ENABLE

X3A/1

SW-ENABLE

Motor

speed

Output stage

enable

(internal)

<15 s (Boot time)

~ 500 ms

5...8 min

VEL0

5

U

U

U

U

U

U

n

t

t

t

t

t

t

t

t

>100 ms

U

This manual is related to the following products: