beautypg.com

7commissioning, 2 initial commissioning – Pilz PSENvip RL D P User Manual

Page 94

background image

7.2

Initial commissioning

7

Commissioning

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

7-10

The adjustment image shown in the illustration below will appear on the
receiver display.

Inbetriebnahme_Erstinbetriebnahme_Empfaenger_ausrichten_Justagebild_mittig_1

Fig. 7-7:

Adjustment image

Inbetriebnahme_Erstinbetriebnahme_Empfaenger_ausrichten_Justagebild_2

The receiver is correctly aligned with the transmitter when:

The cross-hairs of both adjustment templates overlap

The quadrants form a full circle and

The centre point of the upper tool is on the bending line.

The correct adjustment image on the display will look like the image
shown in the illustration below.

Inbetriebnahme_Erstinbetriebnahme_Empfaenger_ausrichten_Justagebild_mittig_2

Fig. 7-8:

Correct adjustment image

Inbetriebnahme_Erstinbetriebnahme_Empfaenger_ausrichten_2

INFORMATION
The adjustment templates have different cut-outs around the
cross-hair (see section entitled "Adjustment templates"). This
makes it easier to evaluate the adjustment direction required by
the transmitter and receiver.