Operating modes during commissioning, Press brake setup mode, Adjustment during initial commissioning – Pilz PSENvip RL D P User Manual
Page 58: 4function description, 6 operating modes during commissioning, 1 press brake setup mode, 2 adjustment during initial commissioning

4.6
Operating modes during commissioning
4
Function Description
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-30
4.6
Operating modes during commissioning
4600
Operating modes during commissioning
4-
Funktion_Betriebsarten_Inbetriebnahme_Allg
The PSENvip has the following options for commissioning:
Press brake setup mode
Adjustment during initial commissioning
Adjustment during tool change
Funktion_Betriebsarten_Inbetriebnahme_Allg_Biegewinkel
Setting the parameters for bending angle measurement
4.6.1
Press brake setup mode
Press brake setup mode
4-
Funktion_Betriebsarten_Inbetriebnahme_Einrichten
Setup mode must be activated when work is to be carried out on the
press brake. The transmitter and receiver must be switched off. The dis-
play is switched on. By switching off the transmitter's light source the
tool setter has visual communication that there is no safety function via
the protected field. The OSSD LED on the receiver lights up red.
The input Power Off = 1 switches off the transmitter's light source.
4.6.2
Adjustment during initial commissioning
Adjustment during initial commissioning
4-
Funktion_Betriebsarten_Inbetriebnahme_Justage_Erstinbetriebnehme
The transmitter and receiver are aligned to each other during initial com-
missioning. The vertical and horizontal alignment is performed using
templates and is displayed on the receiver.
In this operating mode
The protected field is inactive.
The OSSDs are switched off.
There is no protection via the PSENvip.
INFORMATION
Details of the adjustments made during initial commissioning are
described in Chapter 7, "Commissioning", section entitled "Ini-
tial commissioning".