8.2

Operating notes

8

Operation

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

8-4

Press the key to activate bending angle measurement.

The measured value is shown on the receiver's display.
Additional information is only available if the angles to be measured
are set to ACTIVE in the MEASUREMENT menu.

Press the button to obtain additional information.

The display shows the following:

– Angle image
– ANGLE: Measured value
– MARGIN: Specified set value and tolerance

Measured value lies within one of the 5 possible set values:

– MARGIN: Set value and tolerance are displayed, e.g. 90.0/0.5
– LED : lights up blue

Measured value lies within none of the 5 possible set values:

– MARGIN: - / -
– LED : off

Fig. 8-2:

Measure bending angle

Press the or keys to exit bending angle measure-
ment.

SYSTEM OK OSSD OFF

MEASUREMENT

ANGLE

90.4

MARGIN

90.0/0.5