beautypg.com

7commissioning – Pilz PSENvip RL D P User Manual

Page 108

background image

7.5

Setting the parameters for bending angle measurement

7

Commissioning

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

7-24

Parameters for ANGLE 1 to ANGLE 5

ACTIVE

/ INACTIVE

Default setting: INACTIVE

ANGLE 1

to 5

Value range: 0.1 ... 180°, in 0.1° steps
Default setting: 90.0°

MARGIN

Value range: 0.1 ... 10°, in 0.1° steps
Default setting: 1.0

Parameter for ACCURACY

LEVEL

Value range: 1 ... 10
Default setting: 5

The TIME and VALUES parameters cannot be set. They are only dis-
played. Their value depends on the LEVEL parameter.

Value ranges:
TIME

: 20 ... 1800 ms

VALUES

: 1 ... 160

Default setting at LEVEL 5:
TIME

: 450 ms

VALUES

: 40