7commissioning, 3 adjustment during tool change, Ав б д е – Pilz PSENvip RL D P User Manual
Page 103

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
7-19
7.3
Adjustment during tool change
7
Commissioning
Option 2
:
Press the
( ) key to start the Tool Change.
Fig. 7-18:
Tool change menu
1: Tool centre point
2: Range bar
3: Adjustment line
4: Central and rear bending line
5:
No tool identified or vertical position of tool centre point out-
side of the range bar
6:
Receiver insufficiently lit by transmitter
7: Detected tool class
The adjustment line is automatically tracked to the tool centre point.
Inbetriebnahme_Justage_bei_Werkzeugwechsel_durchführen_2
The vertical position of the tool centre point must be within the range
bar. Once the adjustment line is at the top or bottom of the range bar,
the following symbol appears:
.
If the
symbol appears on the display, there is a problem with the
lighting of the receiver by the transmitter:
Check that the transmitter and receiver are aligned correctly. The illu-
minated target area must completely envelop the receiver. If neces-
sary, realign the transmitter (see section entitled "Align transmitter").
Remove any potential contamination on the lens of the transmitter or
receiver.
SYSTEM OK OSSD OFF
TOOL CHANGE
А
В
Б
Д
Е
Tool class 1
Ж
Г