Error messages, 9diagnostics and troubleshooting, 2 error messages – Pilz PSENvip RL D P User Manual
Page 126

9.2
Error messages
9
Diagnostics and Troubleshooting
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
9-4
9.2
Error messages
9200
Error messages
9-
Diagnose_Fehlermeldungen
Error messages appear on the display as soon as an error occurs.
Fig. 9-1:
Error messages on the display
Error message on the display
Error message
Remedy
Not relevant to the user
Press ESC to continue
1.) Acknowledge the error by pressing ESC
Internal error
STOP
1.) Restart the PSENvip: Switch supply volt-
age off and then on again
2.) Change the receiver
Wiring error
1.) Restart the PSENvip: Switch supply volt-
age off and then on again
2.) Ensure that the wiring is correct
3.) Rectify short circuit between the inputs
and/or outputs and 0 V / 24 V
4) Change the receiver
Initial commissioning
1.) Please contact Pilz
No valid data detected (tool and/or
overrun)
1.) Enter overrun and/or make adjustment
during tool change
No adjustment performed after tool
change
1.) Make adjustment during tool change
ERROR
OSSD OFF
NORMAL OPERATION
Error in the
optical system
Not relevant to
the user
Press ESC to proceed
Internal error
STOP
Wiring error
Initial
commissioning
No valid data
detected (tool and/
or overrun)
No adjustment
performed after
tool change